Request Quote
ULMEKA · CAL · MM000020040060080100120140160180200220240260280300
Test systems design

ENGINEERINGTHATVALIDATES

ULMEKA is an international engineering company that designs and builds standard and custom test systems for defense, aerospace, automotive and industry.

104
Test systems
9
System types
23
Standards covered
IPX3–IPX9K + MIL-STD-810 Rain Combined Test Chamber
Standards we design forULMEKA tests your products for compliance with the standards.
/ 01

Five capabilities. One engineering authority.

What we do
/ 02

Free engineering tools.

INTERACTIVE TOOLS
Browse all tools
/ 03
/ 04

Read like
a datasheet.

Rain Test Chambers
IEC 60529 · ISO 20653
IPX3 – IPX4 (Oscillating Tube Tester) – IPX9K Protection Tests
Type
Rain Test Chambers
Standard
IEC 60529
ParameterValueUnit
Internal test volume1500 × 1500 × 1500mm
External dimensions3700 × 2400 × 1700 (W×H×D)mm
CoverageIPX3 / IPX4 / IPX5 / IPX6 / IPX7 / IPX8 / IPX9K + MIL-STD-810 506.6 Proc II
StandardsIEC 60529, MIL-STD-810
Turntable1rpm
Water supplyrecirculating 500 L tank; flow & pressure adjustable
ControlPLC + HMI
Sample capacity100 (standard, extendable)kg
/ 05
Authority standard

MIL-STD-810H — The reference for durability in harsh environments.

ULMEKA engineers chambers and walk-in rooms for MIL-STD-810H: Method 506.6 rain testing under Procedure I, Procedure II and Procedure III, combined rain and IPX integration, and sample-size configurations from cabinet to walk-in.

See MIL-STD-810H portfolio
/ 06

Three ways to access ULMEKA test capability.

Test services
01Buy the SystemFull ownership. Calibration, training and service support included.
02Send Your Product to UsTesting executed in ULMEKA's laboratory. Reporting. Available as a single project or as an ongoing service contract with periodic maintenance and parts coverage.
03Rent with IoT MonitoringChamber on your site. We monitor remotely. Maintenance included.
Discuss Your Testing Requirement
/ 07

Pass compliance the first time.

Test engineering consultancy

We help engineering teams design products that pass MIL-STD-810, IEC, DO-160 compliance testing — the first time.

Pre-compliance review starts in your design phase, not after the first test report. ULMEKA engineers translate standard requirements into testable acceptance criteria, identify failure modes before formal testing, and shape the certification path so each round of testing closes the gap to compliance.

Deliverables are written for audit defensibility: specification documents, test plans, results reports, and standards mapping that survives external review.

Engagements
01Specification writing
02Test plan development
03Report writing
04Audit support
05Training
Discuss your project
/ 08

Trusted across sectors.

Industries served